CASE REPORT Table of Contents   
Year : 2008  |  Volume : 19  |  Issue : 1  |  Page : 94-96
Horner's syndrome following Internal Jugular Vein Dialysis Catheter Insertion


Department of Internal Medicine, Division of Nephrology, King Fahd Medical City, Riyadh, Kingdom of Saudi Arabia

Correspondence Address:
Ashik Hayat
Clinical Fellow Nephrology, University Health Network, Toronto General Hospital, Canada M5B 2E8

Login to access the Email id


PMID: 18087133

Rights and Permissions

Common complications that can occur following internal jugular vein catheterization used for hemodialysis (HD) include internal carotid artery puncture, thrombosis, and infection. We present a case of Horner's syndrome following internal jugular venous cannulation as a possible complication.